Alkaline 9V Battery Specification Sheet

Supreme Power                                                                     Alkaline 9 volt  Product Specifications
_________________________________________________________________________________
Model No: 6LR61

1.  SCOPE:

           This specification is applicable to Alkaline cell, 6LR61 ( mercury and Cadmium Free)
            distributed by Supreme Power battery.

2.   LAW AND REGULATION COMPLIANCE:

           This product complies with EU's battery directive (2006/66/EC)
           Packaging materials comply with EU's directive on packaging materials and waste (94/62/EC)

3.   GENERAL:
            3.1 Type designation
                         IEC/JIS                    6LR61
                         ANSI                       1604A
                         Common                 9V

             3.2 Chemical system: Zn/KOH-H2o/Mn02

             3.3 Nominal Voltage: 9V

              3.4 Weight: 44.0 g

              3.5 Dimension (mm)
                         The dimensions shall be in accordance with the below figures both prior to and after service
                          output test.
                         Measuring equipment shall be with an accuracy of +- 0.05 at least.
                      Alkaline 9 volt dimensions

/

min

max

H

46.5

48.5

S

-

46.4

F

12.45

12.95

L

24.5

26.5

W

15.5

17.5



                   3.6 Capacity: Approximate 500mAh (35mA, 24 h/d, 20 " C, e.v.=5.4V)

             3.7 Operation temperature                                   -18 " C~50 " C
                    Recommended storage temperature              Not to exceed 30" C

4. APPEARANCE

          The battery visually inspected by unaided eye 30cm away from battery.
          The battery shall be free from scratch, rust and extruded internal compounds, such as sealing compounds
          and etc. and sertiuos displacement of artwork.
         Appearance defects shall not be observed that may cause adversely affect actual use of the performance of battery.

5. ELECTRICAL CHARACTERISTICS
         
          Unless otherwise stated, all measurements are to be performed at a
          Standard Environment of                                           20=-2 "C
                                                                                              55=- 20% RH

         
All samples are to normalized for 8 hours at least at the above environment prior to measurement.
          The digital voltmeter (DCM) is with the presion of 1mV (internal resistance not less than 1 Megohm)
          The load resistance of the total circuit is accurate within =-0.5% of the specified value.

          5.1 Open curcuit voltage and closed curcuit voltage (load resistance 180, 03S)

   

OVC (V)

CCV (V)

S.C. (A) (reference)

Intial

Min

9.2

8.8

3.0

Normal

9.6

9.4

4.5

Stored 1 year

Min

9.0

8.5

2.0

Normal

9.4

9.2

3.5

       
         5.2 Service output

Load

35mA

270

620

Background
10,000
Pulse
620

Test Mode

24h/d

1h/d

2h/d

24 h
1 s per h

End Voltage

5.4

5.4 V

5.4V

7.5 V

Applications

Reference

Toy

Radio

Smoke detector

Unit

h

h

h

d

Intial

MAD

13.5

17.5

43.5

17.5

Normal

15.0

19.5

47.0

20.0

Stored
1 year

MAD

12.0

16.5

42.0

16.0

Normal

14.0

18.5

45.0

18.0

     m: minute         h: hour         d: day

     Remark: 1) The intial discharge test shall commence within 30 days of manufacture.
                         During stored period, the calls shall be stored under room temperature conditions.

                    2) Lot release service output test is conducted by 35mA continuous discharging to 5.4 volts
                       - The batteries shall not leak during the service life test before the end of voltage reached.

                   3) The pulse load alone shall be applied across the battery.
                        It is effective load. It is not added in series or parallel to Background load.
       
    6. LEAKAGE RESISTANCE

             6.1 Over discharge leakage test
                     Test conditions: 20=- 2 "  C & RH 60=- 15%, 35mA continuous discharge 48 hours.
                     Number of test samples: 9 batteries
                     Requirement: No visible leakage; No explosion.

              6.2 High temperature leakage test
                      Test conditions: store for 20 days under 60=-2 "C, then store 4~24hours under standard environment.
                      Number of test samples: 9 batteries
                      Requirement: No visible leakage; No explosion.
       
    7. SECURITY CHARACTERISTICS

             7.1 7.1 User drop test
                       This test simulates the situation when a battery is accidentally dropped
                       Test conditions: Un-discharged batteries shall be dropped from a height of 1m onto a concrete surface.
                       Each test battery shall be dropped six times in each of the three directions. The test batteries shall be
                       stored for 1 hour afterwards.
              Number of test sets: 5 batteries
              Requirement: No fire, no explosion or leakage after 1 hour OCV maintenance rate is 95% over

         7.2 Short circuit-proof characteristics
                       This test simulates and external  short circuit of a battery during daily handling of batteries
                       Test conditions:  Positive and negative terminals of an un-discharged battery shall be connected directly.
                       The circuit shall be completed for 24 hours or until battery case temperature has returned to ambient.
                       The resistance of the inter-connecting circuitry shall not exceed 0.1
              Number of  test samples: 5 batteries
              Requirement: No fire or explosion; Leakage allowed

         7.3  Incorrect installation
                      This test simulates incorrect installation of a battery in a series application
                      Test conditions: 4 un-discharged batteries are used per test. 3 batteries are to be placed correctly in series;
                      the 4th battery is reversed with respect to polarity.
                      The circuit is to maintained until venting occurs or the reversed battery temperature has returned to ambient.
               Number of test sets: 5 (20 batteries)
               Requirement: No fire or explosion; Leakage is allowable

    8. EXPIRY DATE

            5 Years

   9.  EXPIRY DATE MARKING

            9.1  Unless otherwise specified, each battery will carry a manufacturing date code followed by month and year of
                   expiry for export. (Shelf life 5 years)

           9.2 For private label, can mark per customers requirements

11. COMPONENTS / INFORMATION ON INGREDIENTS
            Chemical Nature              Alkaline zinc-manganese dioxide batteries

Materials

Approximate
Percentage of
Total Weight
(%)

CAS NO

Materials

Approximate
Percentage of
Total Weight
(%)

CAS NO

Manganese
Dioxide
(MnO2)

~34.0

1313-13-9

Brass

~4.3

12597-71-6

Zinc Powder
(Zn)

~13.0

7440-66-6

FE

~28.0

7439-89-6

Water
(H20

~6.1

7732-18-5

Ni-Plating

~0.3

7440-02-0

Potassium
Hydroxide
(KOH)

~1.5

1310-58-3

Bi

~0.0027

7440-69-9

Carbon

~1.96

7782-42-5

In

~0.0027

7440-74-6

Alkaline 9 volt charge/dis-charge chart

Copy Right-All properties owned by  Supreme Technologies, Inc. and Penny R Stepro  2015

Supreme Power Product Warranty

LifeLight otoscope and ophthalmoscope batteries carry a full 24-month warranty. 
Batteries are dated on the month they are shipped and warranty is good for 24 months thereafter.

Supreme Power LifeLight batteries are not prorated on warranty for time of use.

Find out more

 
 
 

We accept these cards

credit cards accepted
Mailing Address: 359 Hood Road Suite 160 | Jasper, GA 30143 USA

Like to know more?

Interested in our products? Something you are looking for that you don't see on this site? Need Large Quantities of Medical Battery packs assembled... Contact Us with your requirements.

 
Back to top